Thermal Bridge Heat Transfer & Vapour Diffusion Simulation Program AnTherm Version 6.115 - 10.137

[ ↑ ] [ → ] [ToC]

General (control panel)

General (control panel). Light, Beckground, Selected scalar function, Vectorfield, SettingsThe control panel General is used to set and adjust general parameters of the visualization.

More Light Used to turn addition "light sources" on making the the resulting view brighter and displaying more contrast.
Back Color Defines the colour of the background used within graphical window
Perspective Switches the 3D view between perspective projection and parallel projection.
The parallel projection is especially useful during visualization of 3D models or slice views (see also Plan Views).
Function selected By selecting an active function you define which data will be visualized. When additional secondary functions are calculated also (this is set with the switch „Secondary functions") one of following functions can be selected for the 3D visualization:
  • Temperature °C
  • Heat stream density W/m² 
  • Relative condensing surface humidity % (only at the surface of the construction) according to EN ISO 13788:2002, respectively:
    • Condensation
    • Mould growth
    • Corrosion
  • Saturation pressure of vapour hPa
  • Partial pressure of vapour hPa
  • Vapour pressure difference hPa (saturation pressure - partial pressure)
  • Relative Core Humidity % (relative interstitial humidity; interstitial vapour saturation ratio = partial pressure/saturation pressure * 100)
  • Vapour diffusion stream density mg/m²h

Which of these secondary function is actually calculated can be selectively defined within application settings by a parameter "Evaluate which secondary functions?".

If no secondary functions (beyond temperature) are available the field is shown disabled.

Secondary functions When the setting "secondary functions" is tuned off, only temperature distribution within the model is calculated and offered for evaluation.

Turning this setting on requests calculation of additional scalar and vector functions.
Which of these secondary function is actually calculated can be selectively defined within application settings by a parameter "Evaluate which secondary functions?".

Within application settings: Evaluate secondary functions

Vector selected By selecting an active vector field you define which data will be visualized (e.g. during generation of streamlines or vectors (hedgehog, arrows). When additional secondary functions are calculated also (this is set with the switch „Secondary functions") one of following vector fields can be selected for the 3D visualization:
  • Vector field of heat stream W/m²
  • Vector field of the vapour diffusion stream density mg/m²h

Which of these secondary vector field is actually calculated can be selectively defined within application settings by a parameter "Evaluate which secondary functions?".

If there are no vector fields available the field is shown disabled.

Collect Params The current combination of numerous parameters set in all control panels will be saved to the list of Results3D parameters as new entry.
The list of parameters can be edited within Results3D parameters window (e.g. it can be named arbitrarily) or the required parameter combination can be selected from the list and applied to the current Results3D view. This provides the ability to quickly restore earlier saved combination of parameters allowing reproducible visualizations.
The list of parameters is saved within project file.
The Results3D Parameter window will be shown also.
Show Collection The Results3D Parameter window will be shown.
Restore Changes the application settings deciding if the recently used combination of evaluation settings will be restored on initial display of the Results 3D window.
For more details see: Application setting "Restore last Result3D Parameters"

The choice of evaluation function selected and the vector selected retained within application settings and restored respectively.
If the earlier selection is not available within the current data set (i.e. respective secondary function was not calculated) the selection will be reset to default. See also: Selected Function specific evaluation parameters and the application setting "Restore last Result3D Parameters".

Remark: As primary function selected we call the set of values used for current visualization. One can select the temperature, heat stream density, relative surface humidity etc. To reduce the time required for calculation, one can suppress the calculation of secondary functions with the switch "Secondary functions" (creation of data of each separate secondary function requires approximately same time as the creation of the temperature distribution alone when new boundary conditions are applied).
Calculating secondary functions can be significantly improved on multiprocessor systems (MULTICORE-Option).

MULTICORE-option: Speeding up computationally intensive jobs by distributing them on multiple processors or processor cores for parallel execution is only possible with an active MULTICORE-Option of the program. MULTICORE Option in AnTherm

 

Remark: The relative surface humidity is defined only at the component's surface. At adiabatic boundaries (wonder foils) and at surface points hotter then the air space temperature the value of 100% is applied currently.

Following images display visualizations of different primary functions (Temperature °C , heat Stream Density W/m² , Relative Surface Humidity % ):

thermal bridge analysis by showing temperature distribution on the surface of the modelled component thermal bridge analysis by showing heat flux distribution on the surface of the modelled component thermal bridge analysis by showing the condensing humidity distribution on the surface of the modelled component

 

Remark: Producing a visualization of (heat) streamlines requires the calculation of the corresponding vector field of heat (or vapour) stream. Therefore you must turn the calculation of such required secondary vector field on to receive stream line visualizations (i.e. of secondary functions).

VAPOUR-option: Analysis of multidimensional vapour diffusion is only possible with an active VAPOUR-Option of the program.. VAPOUR Option in AnTherm

 

See also: Results3D window, Active (setting), Opaque and Opacity (setting), Colorize (setting), More Light (setting), Background Colour (setting), Main menu, Application settings


 Model, Calculate, Simulate and Analyse Thermal Heat Bridges in 2D and 3D with AnTherm®  